A Low-Cost Fourier-Based Dual-Pump Mock Circulatory Loop for Arterial Pressure Waveform Reproduction
Document Type
Article
Publication Date
2026
DOI
10.3390/bioengineering13101104
Publication Title
Bioengineering
Volume
13
Issue
10
Pages
1104 (25 pp.)
Abstract
Cardiovascular diseases are among the leading causes of death worldwide, creating a need for reliable hemodynamic testing platforms for cardiovascular device evaluation and therapeutic development. Mock circulatory loops (MCLs) provide effective in vitro platforms for reproducing physiological and pathological pressure conditions; however, many existing systems remain limited in programmability, waveform fidelity, standardization, and affordability. This study presents a cost-effective dual-pump hybrid MCL (hMCL) that independently regulates baseline and pulsatile pressure components using Fourier-based harmonic synthesis. Reference arterial pressure waveforms were decomposed into harmonic components, and their amplitudes, frequencies, and phase shifts were converted into pulse-width-modulation signals for dual-pump actuation. Validation using five physiological and virtual arterial pressure waveform datasets demonstrated MAP errors of ≤1.3%, RMSE values of 9.1–24.1 mmHg, and feature errors ≤ 2.8% for systolic, diastolic, and dicrotic notch pressures. Distribution analysis showed small median pressure differences and low variability across waveform characteristics, while repeated hMCL operation demonstrated pressure variations below 3 mmHg. These findings demonstrate that the proposed Fourier-based hMCL provides an accurate, reproducible, and cost-effective platform for arterial pressure waveform reproduction and early-stage cardiovascular device testing. The present validation is pressure-focused; flow waveform fidelity and pressure–flow interactions were not independently characterized.
Rights
© 2026 by the authors.
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution 4.0 International (CC BY 4.0) License.
Data Availability
Article states: "The data presented in this study are derived from publicly available resources, including the PhysioNet CHARIS Database (DOI: 10.13026/C24G6F), the MIMIC-III Waveform Database (DOI: 10.13026/C2294B), the FDA Mock Circulatory Loop Database (DOI: 10.1016/j.compbiomed.2023.106979), and the King’s College London Haemodynamics Database (http://haemod.uk/original, accessed on 15 September 2026). A representative dataset sufficient to reproduce the principal findings of this study has been provided to the publisher and is available with the published article. Additional processed data, MATLAB/Simulink models, Arduino control code, and supporting materials are available from the corresponding author upon reasonable request."
Original Publication Citation
Tsui, V. K., Tavakolian, K., & Ewert, D. (2026). A low-cost Fourier-based dual-pump mock circulatory loop for arterial pressure waveform reproduction. Bioengineering, 13(10), Article 1104. https://doi.org/10.3390/bioengineering13101104
Repository Citation
Tsui, Victor K.; Tavakolian, Kouhyar; and Ewert, Daniel, "A Low-Cost Fourier-Based Dual-Pump Mock Circulatory Loop for Arterial Pressure Waveform Reproduction" (2026). Electrical & Computer Engineering Faculty Publications. 618.
https://digitalcommons.odu.edu/ece_fac_pubs/618
ORCID
0000-0001-5785-358X (Tavakolian)
Included in
Biomedical Engineering and Bioengineering Commons, Cardiovascular System Commons, Hematology Commons, Hemic and Immune Systems Commons