Document Type
Article
Publication Date
2026
DOI
10.3390/s26216832
Publication Title
Sensors
Volume
26
Issue
21
Pages
6832
Abstract
Despite their commercial availability and portability, accelerometers (ACCs) are much less frequently used for arterial pulse waveform (APW) measurement, and the resulting acceleration pulse waveform (APW𝑎) has been much less studied than the APW measured by a tactile sensor. This paper, the first of two parts, presents a theoretical analysis of the feasibility of ACC-based arterial pulse measurement at rest, focusing on the measurement-related technical issues underlying the differences from tactile-based measurement. The tissue–contact–sensor (TCS) stack between the artery and ACC is modeled as a single-degree-of-freedom (SDOF) system to collectively capture the dynamic behavior of all the factors involved during pulse measurement, where motion artifact (MA) is quantified as low-frequency (< 0.7 Hz) mechanical motion of the ACC and alters tissue prestress, resulting in time-varying system parameters (TVSPs) in the SDOF system. Theoretical relations are established among the arterial pulse signal, MA, TCS system parameters, and measured acceleration. The analysis reveals that, even in the absence of MA, the measured acceleration differs fundamentally from the displacement-domain APW because of the dynamic response of the TCS stack and the nonstationary nature of the arterial pulse signal. In the presence of MA, the measured acceleration is affected through two mechanisms: MA itself, represented as baseline drift (BD), and TVSP-induced distortion. While MA itself can be removed using conventional filtering, TVSP-induced distortion is embedded within individual arterial pulse harmonics. Numerical simulations illustrate these effects by comparing displacement- and acceleration-domain signals with and without MA and further demonstrate the distinct effects of TVSP-induced distortion on the instantaneous parameters of a harmonic. These findings provide a theoretical basis for the experimental investigation and evaluation in Part II and a mechanistic basis for MA and sensor-noise removal in ACC-measured pulse signals.
Rights
© 2026 by the authors.
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution 4.0 International (CC BY 4.0) license.
Data Availability
Article states: "The data that support the findings of this study are available upon reasonable request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions."
Original Publication Citation
Hasan, M., & Hao, Z. (2026). Feasibility of Accelerometer-Based Arterial Pulse Measurement: Part I—Theoretical Analysis. Sensors, 26(21), Article 6832. https://doi.org/10.3390/s26216832
ORCID
0009-0006-7544-5938 (Hasan), 0000-0003-2024-1947 (Hao)
Repository Citation
Hasan, Mamun and Hao, Zhili, "Feasibility of Accelerometer-Based Arterial Pulse Measurement: Part 1— Theoretical Analysis" (2026). Mechanical & Aerospace Engineering Faculty Publications. 217.
https://digitalcommons.odu.edu/mae_fac_pubs/217
Included in
Biomedical Engineering and Bioengineering Commons, Cardiology Commons, Physiology Commons