Document Type
Article
Publication Date
2026
DOI
10.1088/2057-1976/aeac32
Publication Title
Biomedical Physics & Engineering Express
Volume
12
Issue
5
Pages
055033 (14 pp.)
Abstract
Smartphone-based sensors may provide a complement to laboratory-based force-plate balance assessment; however, validation studies have not established whether smartphone–force-plate associations and agreement vary across combined manipulations of visual input and support-surface reliability, or which smartphone-derived metrics are most sensitive to sensory challenges. Therefore, this study compared smartphone-derived and force-plate-derived sway metrics during virtual reality-based clinical test of sensory interaction and balance (VR-CTSIB) conditions. This secondary analysis included 40 adults (20 with chronic ankle instability and 20 healthy controls). Participants completed 30 s double-leg stance trials under six VR-CTSIB conditions combining firm or foam surfaces with NormVision, DisplayOff, and SwayRef visual environments. Sway data were collected using a force plate and a smartphone-based head-mounted display. Root mean square (RMS) and mean absolute value (MAV) were calculated in the mediolateral (ML) and anterior–posterior (AP) directions. Pearson correlations with false discovery rate (FDR) correction were used to examine device associations, Bland–Altman analyses assessed agreement, and Cohen’s dz quantified condition sensitivity. In the primary analyses, ML smartphone metrics showed larger correlation coefficients with force-plate measures than AP metrics. The largest correlations were observed in the firm NormVision condition for ML RMS with force-plate ML velocity RMS (r = 0.705, FDR-adjusted p < 0.001) and ML MAV with force-plate ML velocity MAV (r = 0.679, FDR-adjusted p < 0.001). Force-plate outcomes demonstrated greater condition sensitivity than smartphone-derived outcomes. Among smartphone metrics, ML MAV and RMS in the SwayRef condition showed the largest effects (dz = 0.895 and 0.876, respectively). Bland–Altman analyses showed systematic bias, with agreement varying across metrics and conditions. Overall, smartphone-derived sway metrics may provide complementary information during VR-based balance assessment, particularly in the ML direction. However, associations, agreement, and condition sensitivity varied by metric and sensory condition, indicating that smartphone- and force-plate-derived measures should not be interpreted as interchangeable.
Rights
© 2026 The Author.
Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 International License. Any further distribution of this work must maintain attribution to the authors and the title of the work, journal citation and DOI.
Data Availability
Article states: "The data that support the findings of this study are available upon reasonable request from the authors. The data cannot be shared publicly due to ethical restrictions related to participant privacy and the terms of informed consent.
Supplementary tables available at https://doi.org/10.1088/2057-1976/aeac32/data1."
ORCID
0009-0003-5416-7981 (Eshghi), 0000-0002-8949-9471 (Mohammadi), 0000-0002-0101-0986 (Schussler)
Original Publication Citation
Eshghi, S., Mohammadi, A., Schussler, E., & McCann, R. S. (2026). Associations and condition sensitivity of smartphone-and force-plate-derived sway metrics during VR-CTSIB. Biomedical Physics & Engineering Express, 12(5), Article 055033. https://doi.org/10.1088/2057-1976/aeac32
Repository Citation
Eshghi, Saeed; Mohammadi, Amin; Schussler, Eric; and McCann, Ryan S., "Associations and Condition Sensitivity of Smartphone-And Force-Plate-Derived Sway Metrics During VR-CTSIB" (2026). Rehabilitation Sciences Faculty Publications. 185.
https://digitalcommons.odu.edu/pt_pubs/185
Included in
Graphics and Human Computer Interfaces Commons, Rehabilitation and Therapy Commons, Systems and Integrative Physiology Commons