Abstract

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Comments

Published by JACoW Publishing under the terms of the Creative Commons Attribution 3.0 Unported license. Any further distribution of this work must maintain attribution to the author(s), the published article's title, publisher, and DOI.

Original Publication Citation

Li, X., Baumgart, H., Ciovati, G., Hannon, F. E., & Wang, S. (2021). Design of a 10 MeV beamline at the upgraded injector test facility for e-beam irradiation. 12th International Particle Accelerator Conference, May 24-28th, 2021, Campinas, Brazil. http://dx.doi.org/10.18429/JACoW-IPAC2021-WEPAB254