Abstract

Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate (HR), heart rate variability (HRV), respiration rate (RR), respiration modulation (RM), and normalized arterial pulse waveform (APW). Results: RA-derived parameters revealed expected features in the HTx patient at rest, including elevated HR, reduced HRV, and increased arterial stiffness. Although RM increased with harmonic order at rest in the HTx patient, this trend was disrupted at certain post-exercise time points, unlike in the PCI and healthy controls. Both patients exhibited distinct deviations from the healthy control at rest and during recovery. Due to pronounced motion artifacts, CA measurements were unreliable for HRV, RR, and RM, and did not provide additional information, except for the normalized APW. Qualitatively, CA-derived APW indicated markedly increased arterial stiffness in both patients relative to the healthy control, whereas at the RA, arterial stiffness was similar in the two controls and lower than in the HTx patient. Conclusion: Radial arterial pulse signal assessment at rest and during post-exercise recovery provides a reliable, convenient, and low-cost approach for detailed and nuanced evaluation of CV function in a HTx patient. Compared with current clinical tools, this method enables multi-parameter CV characterization from a single pulse signal and shows promise for personalized treatment strategies and long-term CV monitoring.

Rights

© 2026 The Authors

As the Version of Record of this article is going to be / has been published on a gold open access basis under a CC BY 4.0 license, this Accepted Manuscript is available for reuse under a CC BY 4.0 license immediately.

Everyone is permitted to use all or part of the original content in this article, provided that they adhere to all the terms of the Creative Commons Attribution 4.0 International (CC BY 4.0) License.

Although reasonable endeavours have been taken to obtain all necessary permissions from third parties to include their copyrighted content within this article, their full citation and copyright line may not be present in this Accepted Manuscript version. Before using any content from this article, please refer to the Version of Record on IOPscience once published for full citation and copyright details, as permissions may be required. All third party content is fully copyright protected and is not published on a gold open access basis under a CC BY license, unless that is specifically stated in the figure caption in the Version of Record.

Original Publication Citation

Rahman, M. M., Hasan, M., May, J., Herre, J., Reynolds, L., & Hao, Z. (2026). Radial and carotid arterial pulse signals for assessing cardiovascular function at rest and during post-exercise recovery in a heart transplant patient: A case study. Medical Sensors & Imaging. Advance online publication. https://doi.org/10.1088/2977-8425/ae4b40